As of 2021, the monitor is an "old" HP Compaq LA2405x.  This was an older surplus unit, chosen for its scrap bin destiny.  It's fully expected that this monitor may eventually fail due to the corrosive environment it's exposed to in the summer, along with a cold/damp/unconditioned environment in the winter.  Replacement is straightforward; screws accessible on the bottom side release it from the VESA wall mount.  Any monitor with HD or better resolution and an HDMI input should suffice.
The monitor is an "old" HP Compaq LA2405x.  This was an older surplus unit, installed in 2021.  It is/was fully expected that this monitor may eventually fail due to the corrosive environment it's exposed to in the summer, along with a cold/damp/unconditioned environment in the winter.  That said, it's still going strong as of 2025.  Replacement is straightforward; screws accessible on the bottom side release it from the VESA wall mount.  Any monitor with HD or better resolution and an HDMI input should suffice.


== Gauges ==
== Gauges ==
Line 59: Line 59:


=== Filter Tank Pressure ===
=== Filter Tank Pressure ===
[[File:Tank Pressure Gauge Example.png|frame|An example of a tank pressure gauge.]]


Shows the pressure in pounds per square inch (psi) for a [[Sand Filters|sand filter]] tank per the PLC [[Pool Systems Automation#Filter Tank Pressure|Filter Tank Pressure]] measurement (via WiFi link).
Shows the pressure in pounds per square inch (psi) for a [[Sand Filters|sand filter]] tank per the PLC [[Pool Systems Automation#Filter Tank Pressure|Filter Tank Pressure]] measurement (via WiFi link).
Line 95: Line 93:


=== Surge Tank Level ===
=== Surge Tank Level ===
[[File:Surge Tank Depth Gauge Example.png|frame|An example of the surge tank level (depth) gauge.]]


Shows the level (depth) in inches for the surge tank per the PLC [[Pool Systems Automation#Surge Tank Level|Surge Tank Level]] measurement (via WiFi link).
Shows the level (depth) in inches for the surge tank per the PLC [[Pool Systems Automation#Surge Tank Level|Surge Tank Level]] measurement (via WiFi link).
Line 135: Line 131:


=== Out Flow ===
=== Out Flow ===
[[File:Out Flow Gauge Example.png|frame|An example of the out flow rate gauge.]]


Shows the out flow rate in gallons per minute (GPM).
Shows the out flow rate in gallons per minute (GPM).
Line 172: Line 166:


=== Inlet Temperature ===
=== Inlet Temperature ===
[[File:Inlet Temperature Gauge Example.png|frame|An example of the inlet temperature gauge.]]


Shows the inlet temperature in degrees Fahrenheit (°F) per the temperature controller measurement (via WiFi link).  This temperature is measured directly after the filter tanks, prior to the boiler loop (refer to the [[Process Flow Diagram]]).
Shows the inlet temperature in degrees Fahrenheit (°F) per the temperature controller measurement (via WiFi link).  This temperature is measured directly after the filter tanks, prior to the boiler loop (refer to the [[Process Flow Diagram]]).
Line 200: Line 192:


=== pH ===
=== pH ===
[[File:pH Gauge Example.png|frame|An example of the pH gauge.]]


Shows the sampled water pH per a [[Chemtrol Pool Controller]] measurement (via RS-485/Ethernet link).
Shows the sampled water pH per a [[Chemtrol Pool Controller]] measurement (via RS-485/Ethernet link).
Line 236: Line 226:


=== ORP ===
=== ORP ===
[[File:ORP Gauge Example.png|frame|An example of the ORP gauge.]]


Shows the sampled water oxidation reduction potential (ORP) per a [[Chemtrol Pool Controller]] measurement (via RS-485/Ethernet link).
Shows the sampled water oxidation reduction potential (ORP) per a [[Chemtrol Pool Controller]] measurement (via RS-485/Ethernet link).
Line 243: Line 231:
== Graphs ==
== Graphs ==


=== ORP ===
To be updated.
 
[[File:ORP Graph Example.png|frame|An example of an ORP graph.]]
 
The ORP graph shows the ORP measurement over time.  The graph shown contains two days worth of history.  Certain events, marked by numbers, can be identified:
 
# A valley indicates a ORP trend direction change.  This typically occurs when chlorine is added to the pool.
# Overshoot and leveling-off is common overnight, as a lack of UV (and to some extent, pool occupants) prevents the rapid breakdown of chlorine in the pool water.
# Two events are identified in this marker.  First, the gradual drop in ORP as the sun hits the pool (starting at about 7:30 am).  Then, like in #1, a rise in ORP as chlorine is added to the pool.  Overshoot is much lower in this instance, as the pool is occupied and mid-day sunshine contributes to rapid chlorine breakdown.