Power Failure Response: Difference between revisions

Line 29: Line 29:
* Bleed air from all four sand filter tanks.
* Bleed air from all four sand filter tanks.
* Bleed air from the boiler.
* Bleed air from the boiler.
* Reset the low water cut-off on the boiler (as needed).  If there is a call for heat, verify the boiler starts up.  If not, following the [[Pool_Boiler#Troubleshooting|troubleshooting]] steps.
* Reset the low water cut-off on the boiler (as needed).
* If the boiler was operating when power was lost, a thermal trip fault may have occurred.  Clear the fault by pressing the red button on the front of the boiler.
* If the boiler was operating when power was lost, a thermal trip fault may have occurred.  Clear the fault by pressing the red button on the front of the boiler.
* If there is a call for heat, verify that the boiler starts up.  If not, follow the [[Pool_Boiler#Troubleshooting|troubleshooting]] steps.


Note that the ORP probe tends to read low when out of water for a period of time.  Expect the ORP reading to have dropped, resulting in extended chlorinator operation.  Minor overshoot of ORP (and chlorine PPM) may result.
Note that the ORP probe tends to read low when out of water for a period of time.  Expect the ORP reading to have dropped, resulting in extended chlorinator operation.  Minor overshoot of ORP (and chlorine PPM) may result.