| Line 29: | Line 29: | ||
* Bleed air from all four sand filter tanks. | * Bleed air from all four sand filter tanks. | ||
* Bleed air from the boiler. | * Bleed air from the boiler. | ||
* Reset the low water cut-off on the boiler (as needed) | * Reset the low water cut-off on the boiler (as needed). | ||
* If the boiler was operating when power was lost, a thermal trip fault may have occurred. Clear the fault by pressing the red button on the front of the boiler. | * If the boiler was operating when power was lost, a thermal trip fault may have occurred. Clear the fault by pressing the red button on the front of the boiler. | ||
* If there is a call for heat, verify that the boiler starts up. If not, follow the [[Pool_Boiler#Troubleshooting|troubleshooting]] steps. | |||
Note that the ORP probe tends to read low when out of water for a period of time. Expect the ORP reading to have dropped, resulting in extended chlorinator operation. Minor overshoot of ORP (and chlorine PPM) may result. | Note that the ORP probe tends to read low when out of water for a period of time. Expect the ORP reading to have dropped, resulting in extended chlorinator operation. Minor overshoot of ORP (and chlorine PPM) may result. | ||