=== Recirculation Valve ===
=== Recirculation Valve ===


A description is pending.
Adjustments to the recirculation valve require extreme care, especially when the main pump is operating.  The butterfly valve has a tendency to pull itself closed rapidly if the operator is not careful.  Such a rapid change in flow and pressure may cause significant damage to the system.
 
When adjusting the recirculation valve, use the following precautions:
 
* Ideally, turn off the main pump before adjusting.
* If the main pump cannot be stopped, use two hands and extreme care in moving the valve position.  Ensure the valve is locked into a notch before releasing the lever.
* Adjust the position by no more than 1-2 notches in the open or closed direction.  Observe changing in the operating parameters (i.e. boiler manifold temperature) before making additional adjustments.