Tank pressure is lowest when the [[Cleaning the Strainer Basket|strainer basket is clean]] and the sand filters have been recently [[Backwashing|backwashed]].  If pump outflow is restricted enough (in an effort to [[Pool Main Pump#Flow Rate|maintain proper flow]], it is possible for pressure to dip into the "Low Pressure" range.  This is not necessarily a cause for any concern.
Tank pressure is lowest when the [[Cleaning the Strainer Basket|strainer basket is clean]] and the sand filters have been recently [[Backwashing|backwashed]].  If pump outflow is restricted enough (in an effort to [[Pool Main Pump#Flow Rate|maintain proper flow]], it is possible for pressure to dip into the "Low Pressure" range.  This is not necessarily a cause for any concern.
If the associated sensor is in a fault state (the sensor has failed, there is a wiring/fuse fault or the connector is unplugged), the gauge will show a value of 0.0.  A fault state is indicated by the PLC and the stack light.  If the gauge is not visible (the block is blank), a communication error with the PLC has occurred or a software issue is present on the dashboard PC.  Consult the system administrator.