Chemtrol Pool Controller

Revision as of 00:06, 26 August 2020 by Matt Parnell (talk | contribs) (Created page with "==Enabling or Disabling the Chlorinator== The chlorinator is controlled by the Chemtrol unit. The instructions below assume that the Chemtrol unit is operating, and that the...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

Enabling or Disabling the Chlorinator

The chlorinator is controlled by the Chemtrol unit. The instructions below assume that the Chemtrol unit is operating, and that the main screen is visible.

  1. Press the up or down arrow until the ORP readout is highlighted.
  2. Select the ORP sub-menu by pressing the right arrow.
  3. The first item in the ORP sub-menu selects the feed mode. Press the right arrow to change the mode.
  4. Press the up arrow until the ORP feed mode is AUTO to enable or OFF to disable.
  5. Press the left arrow twice to return to the main screen.

On the main screen, an "A" to right of the ORP reading indicates that the chlorinator is enabled (automatic control), "X" indicates it is disabled.

Enabling or Disabling the Acid Pump

The acid pump is controlled by the Chemtrol unit. The instructions below assume that the Chemtrol unit is operating, and that the main screen is visible.

  1. Press the up or down arrow until the pH readout is highlighted.
  2. Select the pH sub-menu by pressing the right arrow.
  3. The first item in the pH sub-menu selects the feed mode. Press the right arrow to change the mode.
  4. Press the up arrow until the pH feed mode is AUTO to enable or OFF to disable.
  5. Press the left arrow twice to return to the main screen.

On the main screen, an "A" to the right of the pH reading indicates that the acid pump is enabled (automatic control), "X" indicates it is disabled.