Line 107: Line 107:
* Must withstand an ambient operating range in the 40 °C to 50 °C (122 °F) range.  For the GS23-2015 at 75% load, 50 °C, no de-rating is necessary up to a 4 kHz carrier frequency (SVPWM mode).
* Must withstand an ambient operating range in the 40 °C to 50 °C (122 °F) range.  For the GS23-2015 at 75% load, 50 °C, no de-rating is necessary up to a 4 kHz carrier frequency (SVPWM mode).
* Must be compatible with 240 VAC high-leg delta.
* Must be compatible with 240 VAC high-leg delta.
 
* A two-channel safety relay will be used.
=== Safety ===
 
A safety relay (reset and E-stop circuits) and additional contactor (maybe two contactors w/o STO) are likely required.
 
A load reactor likely will not be used, nor does it necessarily eliminate the need for shielded VFD cabling.