Pool Boiler Temperature Controller: Difference between revisions

Jump to navigation Jump to search
no edit summary
No edit summary
No edit summary
Line 207: Line 207:
|DigAlarm2
|DigAlarm2
|Triggers a manually-latched alarm per a rising edge on <b>Lgc2 1</b>.  The alarm remains active until acknowledged.
|Triggers a manually-latched alarm per a rising edge on <b>Lgc2 1</b>.  The alarm remains active until acknowledged.
|-
|Instrument
|Provides access to the OP1 and OP2 "beacons" (display indicators) for OP1 and OP2.
|-
|-
|IO.PV
|IO.PV
Line 216: Line 219:
|IO.LgcIO.LB
|IO.LgcIO.LB
|The <b>Main Valve (MV) Active</b> input.
|The <b>Main Valve (MV) Active</b> input.
|-
|IO.Mod 2.A
|The Stage 2 output relay.
|-
|IO.RlyAA
|The Stage 1 output relay.
|-
|-
|Lgc2 1
|Lgc2 1
Line 226: Line 235:
|The output is active if the conditioned RTD measurement is less than the low-temperature threshold.
|The output is active if the conditioned RTD measurement is less than the low-temperature threshold.
|-
|-
|Lgc8 1
|Logically ORs four inputs, all inverted, from <b>Alarm 1</b>, <b>Alarm 2</b>, <b>DigAlarm 2</b> and the signal break output (<b>SBrkOut<b>) from <b>IO.PV</b>.  The output is active unless any of the alarms are triggered or signal break is active.  Essentially inhibits operation of Stage 1 and Stage 2 in the event of a fault condition.
|Loop 1
|Loop 1
|Operates an on-off control loop with a setpoint (Stage 2, displayed on the controller as "Stg2") and feedback via the conditioned RTD measurement.
|Operates an on-off control loop with a setpoint (Stage 2, displayed on the controller as "Stg2") and feedback via the conditioned RTD measurement.