Surge Tank: Difference between revisions
Jump to navigation
Jump to search
→Future Overhaul
Matt Parnell (talk | contribs) |
Matt Parnell (talk | contribs) |
||
| Line 31: | Line 31: | ||
== Future Overhaul == | == Future Overhaul == | ||
=== | === Modulating Drain Valve === | ||
==== Motorized Actuator ==== | |||
A Bray 70-0201H motorized valve has been selected for the application. This is a [https://braycommercialdivision.com/product/series-70-industrial-electric-actuator/ Bray Series 70 Actuator], with a 2,000 in-lb turning capacity, configured for 120 VAC on/off operation. A heater and auxiliary contacts are included. | A Bray 70-0201H motorized valve has been selected for the application. This is a [https://braycommercialdivision.com/product/series-70-industrial-electric-actuator/ Bray Series 70 Actuator], with a 2,000 in-lb turning capacity, configured for 120 VAC on/off operation. A heater and auxiliary contacts are included. | ||
| Line 75: | Line 77: | ||
* The motor has an internal thermal trip set at 135 °C. | * The motor has an internal thermal trip set at 135 °C. | ||
* Terminals are sized for #22 AWG to #14 AWG. | * Terminals are sized for #22 AWG to #14 AWG. | ||
==== Valve ==== | |||
The recommended valve is a Bray 300800-11010119. An exact breakdown of the part number cannot be located, but it appears that it means the following: | The recommended valve is a Bray 300800-11010119. An exact breakdown of the part number cannot be located, but it appears that it means the following: | ||