(Created page with "==Procedure== ===Preparation=== # Turn off the heater. # Disable the chlorinator via the Chemtrol unit. # Disable the acid pump via the Chemtrol unit. # Stop the pump. # Clo...")
 
Line 27: Line 27:
# Open the air bleed valve above the water level sensor on the heater.  If the sensor has tripped, reset.
# Open the air bleed valve above the water level sensor on the heater.  If the sensor has tripped, reset.


==Disabling the Chlorinator==
==Enabling and Disabling the Chlorinator==


The chlorinator is controlled by the Chemtrol unit.  The instructions below assume that the Chemtrol unit is operating, and that the main screen is visible.
The chlorinator is controlled by the Chemtrol unit.  The instructions below assume that the Chemtrol unit is operating, and that the main screen is visible.
Line 34: Line 34:
# Select the ORP sub-menu by pressing the right arrow.
# Select the ORP sub-menu by pressing the right arrow.
# The first item in the ORP sub-menu selects the feed mode.  Press the right arrow to change the mode.
# The first item in the ORP sub-menu selects the feed mode.  Press the right arrow to change the mode.
# Press the up arrow until the ORP feed mode is OFF.
# Press the up arrow until the ORP feed mode is AUTO to enable, OFF to disable.
# The chlorinator is now disabled.  Press the left arrow twice to return to the main screen.
# Press the left arrow twice to return to the main screen.


On the main screen, there should be an "X" to the right of the ORP reading.  This confirms that the chlorinator is disabled.
On the main screen, an "A" to right of the ORP reading indicates that the chlorinator is enabled (automatic control), "X" indicates it is disabled.


==Disabling the Acid Pump==
==Disabling the Acid Pump==