| # Enable the chlorinator via the Chemtrol unit. | | # Enable the chlorinator via the Chemtrol unit. |
| # Open the air bleed valve above the water level sensor on the heater. If the sensor has tripped, reset. | | # Open the air bleed valve above the water level sensor on the heater. If the sensor has tripped, reset. |
|
| |
| ==Enabling or Disabling the Chlorinator==
| |
|
| |
| The chlorinator is controlled by the Chemtrol unit. The instructions below assume that the Chemtrol unit is operating, and that the main screen is visible.
| |
|
| |
| # Press the up or down arrow until the ORP readout is highlighted.
| |
| # Select the ORP sub-menu by pressing the right arrow.
| |
| # The first item in the ORP sub-menu selects the feed mode. Press the right arrow to change the mode.
| |
| # Press the up arrow until the ORP feed mode is '''AUTO''' to enable or '''OFF''' to disable.
| |
| # Press the left arrow twice to return to the main screen.
| |
|
| |
| On the main screen, an "A" to right of the ORP reading indicates that the chlorinator is enabled (automatic control), "X" indicates it is disabled.
| |
|
| |
| ==Enabling or Disabling the Acid Pump==
| |
|
| |
| The acid pump is controlled by the Chemtrol unit. The instructions below assume that the Chemtrol unit is operating, and that the main screen is visible.
| |
|
| |
| # Press the up or down arrow until the pH readout is highlighted.
| |
| # Select the pH sub-menu by pressing the right arrow.
| |
| # The first item in the pH sub-menu selects the feed mode. Press the right arrow to change the mode.
| |
| # Press the up arrow until the pH feed mode is '''AUTO''' to enable or '''OFF''' to disable.
| |
| # Press the left arrow twice to return to the main screen.
| |
|
| |
| On the main screen, an "A" to the right of the pH reading indicates that the acid pump is enabled (automatic control), "X" indicates it is disabled.
| |
|
| |
|
| ==Controlling the Pump== | | ==Controlling the Pump== |
|
| |
|
| * To start or stop the pump, press the black START or red STOP button on the [[Pump Motor Starter]]. | | * To start or stop the pump, press the black START or red STOP button on the [[Pump Motor Starter]]. |