== Stack Light == | |||
The stack light indicates the overall operating state of the system. | |||
{| class="wikitable" | |||
!State | |||
!Description | |||
|- | |||
|None | |||
|The system is off or the pump is starting up. | |||
|- | |||
|Solid Green | |||
|The pump and system are operating nominally. | |||
|- | |||
|Flashing Green | |||
|Same as <b>Green</b> with active pool fill. | |||
|- | |||
|Solid Yellow | |||
|The pump and system are operating but intervention may be required. | |||
|- | |||
|Flashing Yellow | |||
|Same as <b>Yellow</b> with active pool fill. | |||
|- | |||
|Solid Red | |||
|The pump is stopped by the operator. | |||
|- | |||
|Flashing Red | |||
|The pump is stopped due to the surge tank level. | |||
|} | |||
== Drawings == | == Drawings == | ||