The output water flow is monitored by a paddle wheel flow meter that generates a sine wave with a frequency proportional to the flow rate. A flow "transmitter" (GF Signet 8512) translates that analog output from the flow meter into a 4-20 mA signal proportional to the flow rate. | |||
The value is considered valid if the current measured is greater than or equal to 4 mA (not an open circuit). The low and high thresholds are based upon the required flow turnover rate for the pool volume and a maximum to avoid issues (channeling) in the filter tanks. | |||