Cleaning the Strainer Basket: Difference between revisions
→Disabling the Chlorinator
Matt Parnell (talk | contribs) (Created page with "==Procedure== ===Preparation=== # Turn off the heater. # Disable the chlorinator via the Chemtrol unit. # Disable the acid pump via the Chemtrol unit. # Stop the pump. # Clo...") |
Matt Parnell (talk | contribs) |
||
| Line 27: | Line 27: | ||
# Open the air bleed valve above the water level sensor on the heater. If the sensor has tripped, reset. | # Open the air bleed valve above the water level sensor on the heater. If the sensor has tripped, reset. | ||
==Disabling the Chlorinator== | ==Enabling and Disabling the Chlorinator== | ||
The chlorinator is controlled by the Chemtrol unit. The instructions below assume that the Chemtrol unit is operating, and that the main screen is visible. | The chlorinator is controlled by the Chemtrol unit. The instructions below assume that the Chemtrol unit is operating, and that the main screen is visible. | ||
| Line 34: | Line 34: | ||
# Select the ORP sub-menu by pressing the right arrow. | # Select the ORP sub-menu by pressing the right arrow. | ||
# The first item in the ORP sub-menu selects the feed mode. Press the right arrow to change the mode. | # The first item in the ORP sub-menu selects the feed mode. Press the right arrow to change the mode. | ||
# Press the up arrow until the ORP feed mode is OFF. | # Press the up arrow until the ORP feed mode is AUTO to enable, OFF to disable. | ||
# | # Press the left arrow twice to return to the main screen. | ||
On the main screen, | On the main screen, an "A" to right of the ORP reading indicates that the chlorinator is enabled (automatic control), "X" indicates it is disabled. | ||
==Disabling the Acid Pump== | ==Disabling the Acid Pump== | ||