Lighting: Difference between revisions

Jump to navigation Jump to search
no edit summary
No edit summary
Line 5: Line 5:
A Honeywell RPLS740B1008/U has been selected as the standard for this purpose.  It features a 7-day solar time table (for automatic dawn/dusk control) and compatibility with LED and CFL bulbs.  It is rated for:
A Honeywell RPLS740B1008/U has been selected as the standard for this purpose.  It features a 7-day solar time table (for automatic dawn/dusk control) and compatibility with LED and CFL bulbs.  It is rated for:


* 1800 W (15 A) for resistive loads and non-tungsten lights (flourescent, CFL and LED)
* 1800 W (15 A) for resistive loads and non-tungsten lights (flourescent, CFL and LED).
* 1440 W (12 A) for tungsten loads (incandescent/halogen)
* 1440 W (12 A) for tungsten loads (incandescent/halogen).
* 3/4 for motors/fans
* 3/4 HP for motors/fans.


=== Configuration ===
=== Configuration ===
Line 13: Line 13:
The timer is configured as follows:
The timer is configured as follows:


* Latitude of +42° (north) and -83° (west) for Detroit/Livonia, MI
* Latitude of +42° (north) and -83° (west) for Detroit/Livonia, MI.
* A correction factor ("ADJ") of -1 (per the table in the manual)
* A correction factor ("ADJ") of -1 (per the table in the manual).
* A single program (P01) with a turn-on at dusk, and a scheduled turn-off:
* A single program (P01) with a turn-on at dusk, and a scheduled turn-off:
** Midnight for the pool deck post lamps (for post-closing clean-up)
** Midnight for the pool deck post lamps (for post-closing clean-up).
** 2 am for the soffit lights (for aesthetics/security)
** 2 am for the soffit lights (for aesthetics/security).


=== Power Failure ===
=== Power Failure ===