|A regular refresh cycle for the front-desk computer is planned.  The replacement cost is TBD (donated/retired business PCs preferred).
|A regular refresh cycle for the front-desk computer is planned.  The replacement cost is TBD (donated/retired business PCs preferred).
|-
|Electrical
|1966
|2020
|10
|style="background:#C6EFCE|9
|
|TBD
|
|TBD
|<p>Much of the wiring in the clubhouse is original to the 1966 installation.  Fortunately, #12 AWG copper was used throughout, run in rigid conduit.</p><p>In 2020, the wiring was inspected and found to be in good condition.  Nearly all receptacles, switches, and fixtures were replaced.  All associated connections (screws, wire nuts) were removed, cleaned of oxidation, and re-terminated.  Wiring in panels (RLP-1 and RLP-2) was cleaned up, and all branch-side lugs were torqued to spec.</p><p>The basement switchgear was inspected and deemed to be in good operating condition (no replacement planned).</p><p>Replacement of certain receptacles, switches and fixtures may be needed on a 10-year interval.  The cost is TBD.</p>
|-
|-
|Exit Signs
|Exit Signs
Line 197: Line 208:
|-
|-
|Fans (Pedestal)
|Fans (Pedestal)
|1995
|None
|50
|style="background:#C6EFCE|24
|
|
|
|
|There are two pedestal fans (2) in the clubhouse.  One appears to be from 1995, the date of manufacture for the other is not known (TBD).  The fans are anticipated to last beyond the 20 year view (as of 2021).  Small repairs may be needed, cost TBD.
|-
|-